£3,945
All GBP prices are exclusive of UK VAT (where applicable)
Prices exclude local duties – Purchase through your local agent
Therefore, it is important that gloss levels are achieved consistently on every product or across different batches of products.
Gloss has been defined as ‘The attribute of surfaces that causes them to have a shiny or lustrous, metallic appearance’. The gloss of a surface can be greatly influenced by a number of factors. For example, the smoothness achieved during polishing, the amount and type of coating applied, or the quality of the substrate.
Manufacturers design their products to have maximum appeal: from highly reflective car body panels, to glossy magazine covers, or matt finish automotive interior trim.
This is especially noticeable where parts may be produced by different manufacturers or factories, but will be placed adjacent to one another, to create the finished product.
It is important therefore that gloss levels are achieved consistently on every product or across different batches of products.
Gloss can also be a measure of the quality of the surface, for instance a drop in the gloss of a coated surface may indicate problems with its cure, leading to other failures such as poor adhesion or lack of protection for the coated surface.
It is for these reasons that many manufacturing industries monitor the gloss of their products, from cars, printing and furniture to food, pharmaceuticals and consumer electronics.
Designed for the measurement of small and curved surfaces.
Full colour easy to read screen,
display can be rotated from
landscape to portrait
Integrated measurement
button for single handed
operation
Measuring head
Easy to control and take measurements
User definable batch names and batch sizes for quicker and more efficient reporting
Single button push to initiate a defined number of measurements
The gloss measured by the Novo-Gloss Flex 60Â allows the user to quantify and control the surface textures that reduce the perceived quality of manufactured products.
Fast measurement of all parameters. Full on-board statistics with graphical trend analysis and reporting.
Measurement
Simultaneous measurement of all parameters, date and time stamped.
Statistics
Displays full statistics for the number of readings in the current batch.
Graphs
Graphical reporting for quick trend analysis.
Pass / Fail Parameters
Pass / Fail parameters can be defined for instant identification of non-conformances.
Batch names
User definable batch names and batch sizes for quicker and more efficient reporting.
The Novo-Gloss Flex 60 is supplied with interchangeable measurement adaptors.
Standard adaptor
Steel surface adaptor (magnetic)
for increased repeatability for
ferrous materials
Measuring head

The Rhopoint Novo-Gloss Flex 60 can be supplied with a custom measuring adaptor designed to match the
exact geometry of the surface under test.
By tailoring the contact area to the specific shape, the instrument maintains optimal alignment and positioning,
even on components with complex curves, tight radii, or irregular profiles.
This customised approach not only improves repeatability, but also enhances confidence in the measurement data.
Operators can achieve consistent, reliable gloss readings across challenging surfaces such as moulded plastics,
automotive trim, coated metal parts, and formed components.
The adaptor reduces positioning variability, minimises user influence, and supports robust quality control in both
laboratory and production environments.
For manufacturers working with intricate or three-dimensional parts, specifying the correct measuring adaptor
transforms the Flex 60 into a highly adaptable solution, ensuring accurate, repeatable gloss measurement exactly
where it matters.
The Quick Report App from Rhopoint is a quick and easy to use reporting package designed to enhance the functionality & reporting capabilities
| Instrument Information | ||
|---|---|---|
| Operation | Full colour easy to read screen Adjustable brightness 6 button touch sensitive interface | |
| Construction | Integrated calibration holders for error free calibration | |
| Measurement | Fast measurement Results batching with user definable names | |
| Graphical Analysis | On board trend analysis | |
| Statistical Analysis | Max, min, mean, S.D. | |
| Power | Rechargeable lithium ion - 14,000 readings per charge | |
| Memory | 8MB = 2950 readings | |
| Measurement Area (60°) | 6mm x 12mm | |
| Operating Temperature | 15 - 40° C (60 - 104° F) | |
| Humidity | Up to 85%, non condensing | |
| Instrument dimensions | 80 (H) x 150 (W) x 35mm (D), 392g | |
| Measurement head | 60 (H) x 110 (W) x 28mm (D),109g | |
| Packed Weight | 1.6kg | |
| Packed dimensions | 110mm (H) x 280mm (W) x 220mm (D) | |
| Commodity code | 9027 5000 | |
| Standards | ISO 2813, ASTM D523, ASTM D2457, DIN 67530, JIS 8741, JIS K 5600-4-7 | |
| Measurement feature | ||
|---|---|---|
| GU: 60º | Universal angle (all gloss levels) | ||
| Measurement range | 0-125 GU | |
| Resolution | 0.1 GU | |
| Repeatability | ±0.2 GU | |
| Reproducibility | ±0.5 GU | |
| GUh: Improved resolution for low gloss finishes | ||
| Measurement range | 0 -125 GUh (0-12.5 GU) | |
| Resolution | 0.1 GUh (0.01 GU) | |
| Repeatability | ±0.5 GUh (0.05 GU) | |
| Reproducibility | ±2.0 GUh (0.2 GU) | |
| Order Codes | ||
|---|---|---|
| Novo-Gloss Flex 60 | A4000-020.2 | |
| Customer adaptor(requires drawing of the part to be measured in .dxf format) | M4000-505 | |
Free extended 2 year warranty: Requires registration at www.rhopointinstruments.com/help-services/forms-feedback/instrument-registration/ within 28 days of purchase. Without registration, 1 year standard warranty applies.
Guaranteed for the life of the instrument.
Fast and economic service via our global network of accredited calibration and service centres. Please visit www.rhopointinstruments.com/help-services/calibration-servicing/ for detailed information.
| Novo-Gloss Flex 60 | Novo-Gloss Flex 60-X | |
|---|---|---|
| Low gloss standard | ✓ | - |
| High gloss standard | ✓ | ✓ |
| Standard measuring adaptor | ✓ | ✓ (fixed) |
| Steel surface measuring adapter | ✓ | - |
| Calibration certificate for instrument and standards | ✓ | ✓ |
| USB data cable | ✓ | ✓ |
Selecting the correct angle for the application will optimise measurement accuracy. Three types of instruments are available on the market: 60° single angle instruments, a
The diagram above shows the same coating applied to two panels, the first has orange peel/waviness present due to the incorrect application setting on the
Please note, this is NOT a quotation, just a confirmation of the price when purchased in the UK exclusive of VAT/duties